@ -3,32 +3,14 @@ |
|
|
|
#include <RadioLib.h> |
|
|
|
|
|
|
|
// Full receiver reset for all SX126x-family chips (SX1262, SX1268, LLCC68, STM32WLx).
|
|
|
|
// Warm sleep powers down analog, Calibrate(0x7F) refreshes ADC/PLL/image calibration,
|
|
|
|
// then re-applies RX settings that calibration may reset.
|
|
|
|
// RadioLib 7.7.0+ provides resetAGC(): warm sleep powers down analog, Calibrate(0x7F)
|
|
|
|
// refreshes ADC/PLL/image calibration, image is re-calibrated for the operating
|
|
|
|
// frequency, and DIO2 RF switch / RX boosted gain are re-applied automatically.
|
|
|
|
inline void sx126xResetAGC(SX126x* radio) { |
|
|
|
radio->sleep(true); |
|
|
|
radio->standby(RADIOLIB_SX126X_STANDBY_RC, true); |
|
|
|
radio->resetAGC(); |
|
|
|
|
|
|
|
uint8_t calData = RADIOLIB_SX126X_CALIBRATE_ALL; |
|
|
|
radio->mod->SPIwriteStream(RADIOLIB_SX126X_CMD_CALIBRATE, &calData, 1, true, false); |
|
|
|
radio->mod->hal->delay(5); |
|
|
|
uint32_t start = millis(); |
|
|
|
while (radio->mod->hal->digitalRead(radio->mod->getGpio())) { |
|
|
|
if (millis() - start > 50) break; |
|
|
|
radio->mod->hal->yield(); |
|
|
|
} |
|
|
|
|
|
|
|
// Calibrate(0x7F) defaults image calibration to 902-928MHz band.
|
|
|
|
// Re-calibrate for the actual operating frequency.
|
|
|
|
radio->calibrateImage(radio->freqMHz); |
|
|
|
|
|
|
|
#ifdef SX126X_DIO2_AS_RF_SWITCH |
|
|
|
radio->setDio2AsRfSwitch(SX126X_DIO2_AS_RF_SWITCH); |
|
|
|
#endif |
|
|
|
#ifdef SX126X_RX_BOOSTED_GAIN |
|
|
|
radio->setRxBoostedGainMode(SX126X_RX_BOOSTED_GAIN); |
|
|
|
#endif |
|
|
|
#ifdef SX126X_REGISTER_PATCH |
|
|
|
// for improved RX with Heltec v4 — calibration may reset this
|
|
|
|
uint8_t r_data = 0; |
|
|
|
radio->readRegister(0x8B5, &r_data, 1); |
|
|
|
r_data |= 0x01; |
|
|
|
|